STANDBY GENERATOR
OWNER'S MANUAL
This manual should remain with the unit.
A new standard of reliability
Serial Number
1.6L
25kW
Models: 005324-1
005325-1
CAUTION
ONLY QUALIFIED ELECTRICIANS OR CONTRACTORS SHOULD ATTEMPT INSTALLATION!
DEADLY EXHAUST FUMES. OUTDOOR INSTALLATION ONLY!
Not intended for use in critical life support applications.
Cover053A Rev. 0 08/06 Part No. 0G1260A
Przeglądanie stron 0
1 2 3 4 5 6 ... 63 64

Podsumowanie treści

Strona 1 - OWNER'S MANUAL

STANDBY GENERATOROWNER'S MANUALThis manual should remain with the unit.A new standard of reliabilitySerial Number1.6L25kWModels: 005324-1005325-1

Strona 2 - Table of Contents

SPECIFICATIONSGENERATORType ... SynchronousRotor Insulation ...

Strona 3 - WARNING:

COLD WEATHER KITFor cold climates, optional cold weather kit (part number 0F6148) is recommended. The kit includes:• Battery Warmer• 4” Junction Box

Strona 4 - EXPLOSION HAZARDS

GENERATOR AC LEAD CONNECTIONSSee “Voltage Codes”. This generator may be rated at any one of three voltages, either single-phase or three-phase. The el

Strona 5 - INTRODUCTION

INSTALLATIONRefer to the separate “Installation Guide QT Product Line” supplied with the unit.PREPARATION BEFORE START-UPThe instructions in this sect

Strona 6 - IDENTIFICATION RECORD

• Battery charger connection to 120 VAC.• Communication wires connected between transfer switch and generator (HTS only).• Unit secured to pad.STAR

Strona 7 - COOLANT RECOMMENDATIONS

GENERATOR CONTROL AND OPERATIONRefer to the appropriate control panel operator’s manual for this unit.OPERATING UNIT WITH MANUAL TRANSFER SWITCHIf the

Strona 8 - ENGINE PROTECTIVE DEVICES

MAINTENANCE PERFORMED BY SERVICE FACILITIES  Before working on the generator, ensure the fol-lowing:The AUTO/OFF/MANUAL switch is in the OFF positio

Strona 9 - FUEL SYSTEM

Figure 10.1 - Oil Dipstick and Oil Fill CapOIL FILL CAPOILDIPSTICKBATTERY FLUIDCheck battery electrolyte fluid based on the Maintenance Schedule. Flui

Strona 10 - SPECIFICATIONS

CHANGING ENGINE OILRefer to maintenance performed by service facilities for engine oil and filter change frequencies.Drain the oil while the engine is

Strona 11 - Figure 1 — Interconnections

MISCELLANEOUS MAINTENANCECLEANING THE GENERATORKeep the generator as clean and as dry as possible. Dirt and moisture that accumulates on internal gen-

Strona 12 - CONNECTIONS

Standby Generator SetsTable of ContentsSECTION PAGESAFETY RULES ... 1-1INTRODUCTION ...

Strona 13 - PREPARATION BEFORE START-UP

SERVICE SCHEDULEThe following is a recommended maintenance schedule for small standby and residential generator sets. The established intervals in the

Strona 14 - START-UP CHECKLIST

Maintenance Level 1 Level 2 Level 3 Level 4 Tasks Recom- Task Required Task Required Task Task mended Comp. to be done Comp. to be

Strona 15 - Oper001 Rev. 0 08/05

Maintenance Level 1 Level 2 Level 3 Level 4 Tasks Recom- Task Required Task Required Task Task mended Comp. to be done Comp. to be

Strona 16 - Maint011 Rev. D 06/07

TROUBLESHOOTING GUIDEPROBLEM CAUSE CORRECTIONEngine won’t crank. 1. 15 amp fuse blown. 1. Replace fuse. 2. Loose or corroded or defective 2.

Strona 17 - CAN PERFORM

Standby Generator SetsNotes

Strona 18 - Figure 10.2 – Oil Filter

Standby Generator SetsNotes

Strona 19 - MISCELLANEOUS MAINTENANCE

Standby Generator SetsNotes

Strona 20 - SERVICE SCHEDULE

Standby Generator SetsNotes

Strona 22

1 0F7135 1 BREAKER TRAY BACK/BOTTOM 2 0F7022 1 SUPPORT CONTROL PANEL SIDE RH 3 0F7021 1 SUPPORT CONTROL PANEL SIDE LH 4 0F7260 1 COVER CIRCUIT B

Strona 23 - TROUBLESHOOTING GUIDE

Study these SAFETY RULES carefully before install-ing, operating or servicing this equipment. Become familiar with this Owner’s Manual and with the un

Strona 25

ROT0RS BELOW MUST BE VERIFIED BY SERIAL NO. AND B.O.M. 1 0G2927 1 RTR-102-20.0AD1 CPL (2006) (FOR UNITS BUILT AFTER FEBRUARY 2007) 0G2827 1

Strona 27

COMPONENTS INCLUDED IN 0G3365E 1 0F1823A 1 ENCL HSB CONTROL PANEL 2 0F3078 1 COVER CONTROL PANEL 3 0F2606 1 HINGE CONTINUOUS H-PANEL 4 036

Strona 29

1 0F7211 1 SUPPORT RADIATOR LH SIDE 2 0G0760 1 VENTURI 16" DIA FAN 3 0F7210 1 SUPPORT RADIATOR RH SIDE 4 0E9837B 1 RADIATOR 1.6L CHY 5 0F0

Strona 31

1 0F3408B 1 BATTERY TRAY C1 CPL 2 0F3411 1 STRAP BATTERY RETAINMENT 3 025507 1 WASHER SHAKEPROOF EXT 7/16 STL 4 059980 1 SCREW HHC M10-1.5 X 2

Strona 33

1 0G0759 1 MOUNTING BASE 1.6L2 027482 2 WASHER SHAKEPROOF EXT 5/16 STL3 070936 2 DAMPENER VIBRATION4 070936C 2 VIB. ISO. 70-75 DURO5 039253 8 SCREW HH

Strona 34

• Before performing any maintenance on the gen-erator, disconnect its battery cables to prevent accidental start-up. Disconnect the cable from the bat

Strona 36

1 098290 1 ASM MOTOR STEPPER2 098941A 1 HOUSING GOVERNOR CONNECTOR3 098958A REF CONNECTOR INTERFACE ASSEMBLY4 098942A 1 COVER CONNECTOR HOUSING5 09822

Strona 38

1 0G0207 REF ENGINE GENERAC 1.6L NG 2 0G0834 1 ENGINE PLATE 1.6L 3 0G0820 REF HOUSING BLOWER MACHINED 1.6L 4 0E9747 1 STARTER 12 VOLT 5 0

Strona 40

1 026812 2 ELBOW 90D 3/4 NPT 2 075580 1 FLANGE FUEL INLET 3 0G1397 1 FUEL REGULATOR 1.6L REWORK 4 039253 2 SCREW HHC M8-1.25 X 20 G8.8 5 022

Strona 42

1 0F7003 (XX) 1 ROOF C1 CPL2 0F7004 (XX) 1 CORNER POST LH SIDE C1 CPL3 0F7008 (XX) 1 DOOR REAR C1 CPL4 0F7005 (XX) 1 CORNER POST RH SIDE C1 CPL5

Strona 44

1 0F7366 1 MUFFLER C1 2 0F7647 1 MUFFLER SADDLE 3 0F8095 1 PIPE EXHAUST OUTLET 4 0F7538 1 PIPE EXH INLET MUFLR SIDE 1.5L 5 0E3257 4 SCREW HWH

Strona 45

1-3INTRODUCTIONThank you for purchasing this model of the standby generator set product line.Every effort was expended to make sure that the informati

Strona 56

IDENTIFICATION RECORDDATA LABELEvery generator set has a DATA LABEL that contains important information pertinent to the generator. The data label, wh

Strona 61

Standby Generator SetsWarrantyPrinted in U.S.A.GENERAC POWER SYSTEMS STANDARD LIMITED WARRANTY FORHOME STANDBY/LIGHT COMMERCIAL PRODUCT 45kW AND BELOW

Strona 62

EQUIPMENT DESCRIPTIONThis equipment is a revolving field, alternating cur-rent generator set. It is powered by a gaseous fueled engine operating at 18

Strona 63

ENGINE PROTECTIVE DEVICESThe standby generator may be required to operate for long periods of time without an operator on hand to monitor such engine

Strona 64 - Warranty

FUEL SYSTEMFUEL REQUIREMENTSThe standby generator may be equipped with one of the following fuel systems:• Natural gas fuel system• Propane vapor (P